480W/48V Industrial DIN Rail Power Supply-RTG480-48W

Model: RTG480-48W

Power Input: AC 90~264V                     

Support production for short circuit/over

current/over voltage

Wide operation temperature range:-40C~70C

100% full load aging test

High efficiency, long life time and high Reliability

Meet EMC Standard

Support OEM/ODM services

CE FCC ROHS CCC Certificate



Description

RTG480-48  is  one  economical  slim  480W  industrial  DIN  Rail  power  supply  series, adapting to be installed on TS-35/7.5 or TS-35/ 15 mounting rails. 

The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.


RTG480-48 is designed with a metal shell, which is easy to increase the heat dissipationof the machine. The working efficiency is as high as 90%. The product can

 work in -40C to  70Cambient temperature under the condition of air circulation. It has a constant current mode overload protection functionand is suitable for various

 Inductive or capacitive load  applications, complete protection functions and compliance with industrial control equipment certifications, making RTG480-48 a very 

competitive power solution for industrial  applications.


Technical Specification

Model

RTG480-48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Group of Output

1

DC Voltage

DC 48V

Default Output Voltage

48.00-48.2V   (VIN: 220VAC / LOAD: 0A)

Output Rated Current

10A

Output Current Range

0-10A

Output Rated Power

720W

Total Peak Output

Power

Up to 720W(Sustainable time 10S/220VAC)

Peak Output Current

15A( Sustainable time 10S/220VAC)

 

Ripple noise

Peak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0. 1uF and 47uF, testing at 20MHz)

Output Regulation

Range

47~56V

Stabilized Voltage

Precision

± 1% (@ 90V-264Vac input, 100% load)

Line Regulation

±1% (@ 90-264Vac input, 100% load)

Load Regulation

± 1% (@ 90-264Vac input, 0- 100% load)

Output Start Time

< 2S @ nominal input (100% load )

Output Hold Time

> 20ms @ 115Vac,

> 115 ms @ 230Vac (100% load )

Voltage Overshoot

≤5%

 

 

 

 

 

 

 

Input

Input Voltage Range

90~264VAC

Input Rated Voltage Range

100~240VAC

Frequency Range

47~63Hz

Rated Frequency

50/60Hz

Starting Voltage

90Vac

Efficiency

> 87.0% @ 115Vac, > 92.0% @ 230Vac

Input Current @25C

< 8.80A @ 115Vac, < 4.40A @ 230Vac

Inrush Starting Current @25C

< 35A @ 115Vac & 230Vac

Power Factor

> 0.99 @ 115Vac,

> 0.93 @ 230Vac


 

 

 

 

 

 

 

 

 

 

Protection

 

 

 

 

 

 

 

 

 

 

Output

 

Over power

576~720W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.)

 

Over voltage

57~70V Swing machine (Short circuit the  Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit)       Note: Do not use external voltage.

 

Over current

12~15A Swing machine (Testing method:      Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)

 

 

Short circuit

It achieves the long-term short circuit by     connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with    power output port. Self-recovery to normal after removing the short circuit.

 

 

 

 

 

Operation Environment

Operation Temperature and Humidity

-40C~70C;   20%~95%RH

Storage Temperature and Humidity

--40C~85C;   10%~95%RH non-condensing

Temperature Coefficient

±0.03%/C (0~50C)

 

Libration

Frequency range: 10 ~ 500Hz,

Acceleration: 2G,                                

 Each sweep cycle 10min.                    

Six sweeps along the X, Y, and Z axis

 

Surge

Acceleration: 20G,

Duration time: 11mS,

Three shocks along X, Y and Z axis

Altitude

 

2000m

 

 

 

 

 

 

Safety and

EMC

Standard @25C

 

 

 

Security Standard

GB4943/EN60950

Reference   Certification

 

Dielectric Strength

InputOutput:3KVac/10mA;

Input--Case:1.5KVac/10mA;

Output---Case:0.5KVDC/ 10mA

Time for each testing is 1min.

Grounding Test

Test Condition: 32A/2min; Ground bond:   0. 1 ohms.

Leakage Current @25C


 

Input to GND ≤3.5mA; Input to output ≤0.25mA   (Input 264Vac, 63Hz)

Insulation

Resistance


Input—Output: 10M ohms;

EMI

Conducted

Interference

EN55022, EN55024, FCC PART 15 CLASS B




Radiated

Interference

EN55022, EN55024, FCC PART 15 CLASS B

Harmaonic current

EN61000-3-2   CLASS D

 

 

 

 

 

 

EMS

Conducted

Emission

EN61000-4-6 Level3

Radiated Emission

EN61000-4-3 Leve3 criterion B

Power Frequency Emission

EN61000-4-8 Level3

Electrostatic

Emission

EN61000-4-2 Level4 criterion B

EFT

EN61000-4-4 Level4 criterion B

Surge

EN61000-4-5 Level4 criterion B

Dip and Interruption

EN61000-4- 11

Dimensions (W*H*D)

130.5*124*45mm

 


24W/24V Industrial DIN rail power supply RTG24W-24V

RTG24W-24V

36W/24V Industrial DIN rail power supply RTG36W-24V

RTG 36W-24V

480W/24V Industrial DIN Rail Power Supply-RTG480-24W

RTG480-48W

60W/12V Industrial DIN Rail Power Supply-RTG60-12W

RTG60-12W